MCS180x Linear Hall-Effect Current Sensors

Monolithic Power Systems (MPS) MCS180x Linear Hall-Effect Current Sensors feature a small footprint that saves board space and is well-suited for space-constrained applications. The series is offered in SOIC-8 packaging with a tape-and-reel option. The MCS180x modules are used for AC and DC current sensing. The Hall array is differential, which cancels out the stray magnetic field. These sensors provide two power supply options (3.3V or 5V) and a wide current range for the best accuracy in different applications. Other features include adjustable bandwidth up to 100kHz, 4μs output rising time, and -40°C to +125°C operating temperature range. Typical applications for MPS MCS180x Linear Hall-Effect Current Sensors include motor controls, automotive systems, load detection and management, switch-mode power supplies, and overcurrent fault protection.

Resultados: 31
Selecionar Imagem Número de peça Fabricante Descrição Ficha técnica Disponibilidade Preços (USD) Filtrar os resultados na tabela por preço unitário baseado na sua quantidade. Qtde RoHS Modelo ECAD Potência nominal Tipo de sensor Tempo de resposta Precisão Intervalo de frequência Tensão de alimentação operacional Tipo de saída
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 5V Hall current sensor. 2.5% accuracy. 200V Isolation 1,779Em estoque
Mín.: 1
Mult.: 1
: 2,500
12.5 A Current Sense 5 us 3 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 5V Hall current sensor. 1.5% accuracy. 2.4kV Isolation 1,169Em estoque
Mín.: 1
Mult.: 1
: 500

50 A Current Sense 5 us 5 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 5V Hall current sensor. 1.5% accuracy. 2.4kV Isolation 741Em estoque
Mín.: 1
Mult.: 1
: 500

20 A Current Sense 5 us 5 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 3.3V Hall current sensor. 2.5% accuracy. 200V Isolation 647Em estoque
Mín.: 1
Mult.: 1
: 500

10.5 A Current Sense 5 us 3 % 100 kHz 3.3 V Ratiometric
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation 537Em estoque
Mín.: 1
Mult.: 1
: 500

40 A Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 5V Hall current sensor. 1.5% accuracy. 2.4kV Isolation 2,240Em estoque
Mín.: 1
Mult.: 1
: 2,500

5 A Current Sense 5 us 5 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 5V Hall current sensor. 2.5% accuracy. 200V Isolation 187Em estoque
Mín.: 1
Mult.: 1
: 500

12.5 A Current Sense 5 us 3 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 5V Hall current sensor. 2.5% accuracy. 200V Isolation 259Em estoque
Mín.: 1
Mult.: 1
: 500

25 A Current Sense 5 us 3 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation 82Em estoque
15,000No pedido
Mín.: 1
Mult.: 1
: 2,500

5 A Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation 9Em estoque
5,000No pedido
Mín.: 1
Mult.: 1
: 2,500

20 A Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation 25Em estoque
2,500Esperado 16/09/2026
Mín.: 1
Mult.: 1
: 2,500

30 A Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 5V Hall current sensor. 1.5% accuracy. 2.4kV Isolation 403Em estoque
Mín.: 1
Mult.: 1
: 500

10 A Current Sense 5 us 5 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 5V Hall current sensor. 1.5% accuracy. 2.4kV Isolation 287Em estoque
Mín.: 1
Mult.: 1
: 500

40 A Current Sense 5 us 5 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation
1,000Esperado 17/07/2026
Mín.: 1
Mult.: 1
: 500

5 A Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation
1,681No pedido
Mín.: 1
Mult.: 1
: 500

10 A Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 5V Hall current sensor. 1.5% accuracy. 2.4kV Isolation
5,000Esperado 02/12/2026
Mín.: 1
Mult.: 1
: 2,500

10 A Current Sense 5 us 5 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 5V Hall current sensor. 1.5% accuracy. 2.4kV Isolation
2,494Esperado 06/07/2026
Mín.: 1
Mult.: 1
: 2,500

10.5 mA Current Sense 5 us 2.5 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 3.3V Hall current sensor. 2.5% accuracy. 200V Isolation
500Esperado 21/10/2026
Mín.: 1
Mult.: 1
: 500

10.5 A Current Sense 5 us 3 % 100 kHz 3.3 V Ratiometric
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation
500Esperado 07/10/2026
Mín.: 1
Mult.: 1
: 500

20 A Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 5V Hall current sensor. 1.5% accuracy. 2.4kV Isolation
500Esperado 10/09/2026
Mín.: 1
Mult.: 1
: 500

10.5 mA Current Sense 5 us 2.5 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 3.3V Hall current sensor. 2.5% accuracy. 200V Isolation Tempo de conclusão sem o estoque 34 semanas
Mín.: 1
Mult.: 1
: 2,500

8.5 mA Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 3.3V Hall current sensor. 2.5% accuracy. 200V Isolation Tempo de conclusão sem o estoque 34 semanas
Mín.: 1
Mult.: 1
: 2,500

8.5 mA Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 5V Hall current sensor. 2.5% accuracy. 200V Isolation Tempo de conclusão sem o estoque 34 semanas
Mín.: 2,500
Mult.: 2,500
: 2,500

25 A Current Sense 5 us 3 % 100 kHz 5 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation Tempo de conclusão sem o estoque 34 semanas
Mín.: 1
Mult.: 1
: 2,500

10 A Current Sense 5 us 3.3 V Analog
Monolithic Power Systems (MPS) Sensores de Corrente de Montagem de Painel 3.3V Hall current sensor. 1.5% accuracy. 2.4kV Isolation Tempo de conclusão sem o estoque 38 semanas
Mín.: 1
Mult.: 1
: 500

30 A Current Sense 5 us 3.3 V Analog